Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(10): e0291593, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37862307

RESUMO

Polysomnographic sleep architecture parameters are commonly used to diagnose or evaluate treatment of sleep disorders. Polysomnography (PSG) having practical constraints, the development of wearable devices and algorithms to monitor and stage sleep is rising. Beside pure validation studies, it is necessary for a clinician to ensure that the conclusions drawn with a new generation wearable sleep scoring device are consistent to the ones of gold standard PSG, leading to similar interpretation and diagnosis. This paper reports on the performance of Somno-Art Software for the detection of differences in sleep parameters between patients suffering from obstructive sleep apnea (OSA), insomniac or major depressive disorder (MDD) compared to healthy subjects. On 244 subjects (n = 26 healthy, n = 28 OSA, n = 66 insomniacs, n = 124 MDD), sleep staging was obtained from PSG and Somno-Art analysis on synchronized electrocardiogram and actimetry signals. Mixed model analysis of variance was performed for each sleep parameter. Possible differences in sleep parameters were further assessed with Mann-Whitney U-test between the healthy subjects and each pathology group. All sleep parameters, except N1+N2, showed significant differences between the healthy and the pathology group. No significant differences were observed between Somno-Art Software and PSG, except a 3.6±2.2 min overestimation of REM sleep. No significant interaction 'group'*'technology' was observed, suggesting that the differences in pathologies are independent of the technology used. Overall, comparable differences between healthy subjects and pathology groups were observed when using Somno-Art Software or polysomnography. Somno-Art proposes an interesting valid tool as an aid for diagnosis and treatment follow-up in ambulatory settings.


Assuntos
Transtorno Depressivo Maior , Apneia Obstrutiva do Sono , Humanos , Polissonografia , Sono , Apneia Obstrutiva do Sono/diagnóstico , Software
2.
Sleep Med ; 96: 14-19, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35576829

RESUMO

The visual scoring of gold standard polysomnography (PSG) is known to present inter- and intra-scorer variability. Previously, Somno-Art Software, a cardiac based sleep scoring algorithm, has been validated in comparison to 2 expert visual PSG scorers. The goal of this research is to evaluate the performances of the algorithm against a pool of scorers. Sixty PSG and actimetry recording nights, representative of clinical practice (healthy subjects and patients suffering from obstructive sleep apnea [OSA], insomnia or major depressive disorder), were scored by 5 different sleep scoring centers and by the Somno-Art Software. Intra-class correlation coefficient (ICC) and Wilcoxon Signed-Rank Test were calculated between each scorer and the average value of the 6 scorers, including Somno-Art Software. In addition, epoch-by-epoch agreement between scorers were analyzed. Somno-Art Software estimation of sleep efficiency, wake, N1+N2, N3 and REM sleep fit within the interscorer range for the full dataset and the subgroups, except for underestimating N3 sleep in OSA patients. Additionally, Somno-Art Software overestimated sleep latency compared to the average scoring for insomniacs (+4.7 ± 1.6min). On the full dataset, Somno-Art Software had good (0.75 < ICC<0.90) or excellent (ICC>0.90) ICC scores for all sleep parameters except N3 sleep (moderate score, 0.50 < ICC<0.75). For the 4-stages epoch-by-epoch agreement, Somno-Art Software was slightly below that of the visual scorers except for the healthy sub-group where an overlap was demonstrated. Somno-Art Software sleep scoring shows a good interscorer reliability in the range of the 5 visual polysomnography scorers.


Assuntos
Transtorno Depressivo Maior , Apneia Obstrutiva do Sono , Humanos , Polissonografia , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/diagnóstico , Fases do Sono , Software
3.
Sleep Adv ; 3(1): zpab019, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37193409

RESUMO

Study Objectives: Integrated analysis of heart rate (electrocardiogram [ECG]) and body movements (actimetry) during sleep in healthy subjects have previously been shown to generate similar evaluation of sleep architecture and continuity with Somno-Art Software compared to polysomnography (PSG), the gold standard. However, the performance of this new approach of sleep staging has not yet been evaluated on patients with disturbed sleep. Methods: Sleep staging from 458 sleep recordings from multiple studies comprising healthy and patient population (obstructive sleep apnea [OSA], insomnia, major depressive disorder [MDD]) was obtained from PSG visual scoring using the American Academy of Sleep Medicine rules and from Somno-Art Software analysis on synchronized ECG and actimetry. Results: Inter-rater reliability (IRR), evaluated with 95% absolute agreement intra-class correlation coefficient, was rated as "excellent" (ICCAAAvg95% ≥ 0.75) or "good" (ICCAAAvg95% ≥ 0.60) for all sleep parameters assessed, except non-REM (NREM) and N3 sleep in healthy participants (ICCAAAvg95% = 0.43, ICCAAAvg95% = 0.56) and N3 sleep in OSA patients (ICCAAAvg95% = 0.59) rated as "fair" IRR. Overall sensitivity, specificity, accuracy, and Cohen's kappa coefficient of agreement (κ) on the entire sample were respectively of 93.3%, 69.5%, 87.8%, and 0.65 for wake/sleep classification and accuracy and κ were of 68.5% and 0.55 for W/N1+N2/N3/rapid eye movement (REM) classification. These performances were similar in healthy and patient population. Conclusions: The present results suggest that Somno-Art can be a valid sleep-staging tool in both healthy subjects and patients with OSA, insomnia, or MDD. It could complement existing non-attended techniques measuring sleep-related breathing patterns or be a useful alternative to laboratory-based PSG when this latter is not available.

4.
Am J Psychiatry ; 174(12): 1195-1202, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-28750582

RESUMO

OBJECTIVE: The authors assessed the efficacy, safety, and tolerability of MIN-101, a compound with affinities for sigma-2 and 5-HT2A receptors and no direct dopamine affinities, in comparison with placebo in treating negative symptoms in stabilized patients with schizophrenia. METHOD: The trial enrolled 244 patients who had been symptomatically stable for at least 3 months and had scores of at least 20 on the negative subscale of the Positive and Negative Syndrome Scale (PANSS). After at least 5 days' withdrawal from all antipsychotic medication, patients were randomly assigned to receive placebo or 32 mg/day or 64 mg/day of MIN-101 for 12 weeks. The primary outcome measure was the PANSS negative factor score (pentagonal structure model). Secondary outcome measures were PANSS total score and scores on the Clinical Global Impressions Scale (CGI), the Brief Negative Symptom Scale, the Brief Assessment of Cognition in Schizophrenia, and the Calgary Depression Scale for Schizophrenia. RESULTS: A statistically significant difference in PANSS negative factor score was observed, with lower scores for the MIN-101 32 mg/day and 64 mg/day groups compared with the placebo group (effect sizes, d=0.45 and d=0.57, respectively). Supporting these findings were similar effects on several of the secondary outcome measures, such as the PANSS negative symptom, total, and activation factor scores, the CGI severity item, and the Brief Negative Symptom Scale. There were no statistically significant differences in PANSS positive scale score between the MIN-101 and placebo groups. No clinically significant changes were observed in vital signs, routine laboratory values, weight, metabolic indices, and Abnormal Involuntary Movement Scale score. CONCLUSIONS: MIN-101 demonstrated statistically significant efficacy in reducing negative symptoms and good tolerability in stable schizophrenia patients.


Assuntos
Indóis/uso terapêutico , Esquizofrenia/tratamento farmacológico , Psicologia do Esquizofrênico , Adolescente , Adulto , Antipsicóticos/uso terapêutico , Método Duplo-Cego , Feminino , Humanos , Indóis/efeitos adversos , Masculino , Pessoa de Meia-Idade , Escalas de Graduação Psiquiátrica , Resultado do Tratamento , Adulto Jovem
5.
Sleep Med ; 21: 47-56, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27448472

RESUMO

OBJECTIVE: The objective of the study was to evaluate the reliability of a new methodology for assessing sleep architecture descriptors based on heart rate and body movement recordings. METHODS: Twelve healthy male and female subjects between 18 and 40 years of age, without sleep disorders and not taking any drug or medication that could affect sleep, were recorded continuously during five consecutive nights. Together with the standard polysomnography, heart rate was recorded with a Holter and wrist movements by actimetry. Of the 60 recorded nights, 48 artifact-free nights were analyzed by two independent and well-trained visual scorers according to the rules of the American Academy of Sleep Medicine. Sleep stages were assigned to every 30-s epoch. In parallel, the same nights were analyzed by the new methodology using only heart rate and actimetry data, allowing a 1-s epoch sleep stage classification. Sleep architecture was measured for 48 nights, independently for the two manual scorings and the automatic analysis. RESULTS: Over 42 nights, the intra-class correlation coefficient, used to assess the consistency or reproducibility of quantitative measurements made by different observers, was classified as excellent when all 12 descriptors were combined. Analyses of the individual descriptors showed excellent interclass correlation for eight and good for four of the 12. CONCLUSION: The automatic analysis of heart rate and body movement during sleep allows for the evaluation of sleep architecture and continuity that is equivalent to those obtained by manual scoring of polysomnography. The technique used here is simple and robust to allow for home sleep monitoring.


Assuntos
Voluntários Saudáveis , Frequência Cardíaca/fisiologia , Polissonografia/métodos , Fases do Sono/fisiologia , Punho , Actigrafia/métodos , Adulto , Processamento Eletrônico de Dados , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...